5 plus years' experience for the HVAC Techs and commercial/ industrial experience only, no residential.
OR
5 plus years' experience for the Electrical Maintenance Techs and commercial/ industrial experience only, no residential. Ideally with Journeymen Masters
AND ALL CANDIDATES WILL REQUIRE
Secret clearance required; we can process individuals so long as they are willing & able.
About us: We design, build, operate, and maintain cyber-physical solutions for the nation’s most recognizable mission-critical facilities, secure environments, complex infrastructure, and global enterprises. The company’s capabilities include electrical, electronic security, telecommunications, life-safety, instrumentation and control, and command and control systems. M.C. Dean is headquartered in Tysons, Virginia, and employs more than 5,100 professionals who engineer and deploy automated, secure, and resilient power and technology systems; and deliver the management platforms essential for long-term system sustainability.
Job Description:
Responsible for ensuring that all electrical, mechanical, and fire/life safety equipment within the data center is operating at peak efficiency. This involves both planned preventative maintenance of equipment, daily corrective work, and emergency response to emergent issues. The technician serves as an expert technical resource reporting to a program manager, interacting with Onsite Engineering Operations (OEO) and any third party vendors. They are expected to be a singular focal point for all facility operations within a given data center and to support operated data centers. Data center equipment that supports mission-critical servers must maintain better than 99.999% uptime.
- Utilizes safe working practices; can apply lockout/tagout, SDS, applies good housekeeping methods, etc. Ability to type and utilize common administrative and office software.
- Reads and reviews blueprints, floor plans, wiring diagrams, mechanical riser drawings, and job specifications.
- Ability to use hand tools and test equipment to install, troubleshoot, and repair new or replacement parts for existing units.
- Daily walk-through of facility documenting parameters such as power availability, temperature and humidity, alarm status, etc. to be catalogued and compared for identification of discrepancies and trends.
- Ability to understand site-specific processes and procedures such as how to report an incident or outage, procedure execution, PM standards, CMMS system, as well as the use of Sharepoint to access CE procedures and training content.
- Ability to learn how to access the site primary and secondary EOP's, and understand the purpose of each of the EOP's and the critical nature of being an operator and first responder in the datacenter.
- Navigate and verify the nominal status of the electrical and mechanical infrastructure via the BMS and EPMS systems, following site MOP & SOP procedures.
Requirements:
- Requires a High School Diploma or equivalent with 4+ years of experience.
- Ability to obtain a Secret security clearance, Active Clearance Preferred but not Required.
Preventive and Corrective Maintenance:
- Air Cooled Chillers
- Air Handling Units
- Boilers
- Cooling Towers
- Data Center Cooling
- Exhaust and Filtration
- Heat Exchangers
- Heat Pumps
- Humidification
- Piping repairs
- Pumps
- Rooftop Units
- Variable Air Volume Systems
- Variable Frequency Drives (VFD)
- Walk-in Coolers and Freezers
Projects:
- AC Unit installs.
- Air-cooled chiller installation
- Boiler overhauls and replacements
- Commercial water heater installation
- Pump rebuilds and installation – water cooled and direct expansion.
Responsibilities:
- Perform maintenance on Engineering systems and equipment to include such items as, but not limited to, Chiller, IFU, VAV, HVAC Controls, and fire and life safety system sprinkler systems
- Operate and maintain critical systems such as HVAC, CRAC units, life safety and building automated systems, and utility systems.
Job Type: Full-time
Pay: $25.00 - $40.00 per hour
Benefits:
- 401(k)
- Dental insurance
- Health insurance
- Life insurance
- Paid time off
- Vision insurance
Experience level:
Work setting:
Experience:
- Data center: 2 years (Preferred)
- Electrical / Mechanical: 5 years (Preferred)
Security clearance:
Ability to Relocate:
- Columbus, OH: Relocate before starting work (Required)
Work Location: In person